YM-2U23A Differential Pressure Leak Detector Instructions
This series of instruments uses a self-developed dedicated control board for control and calculation. Coupled with high-precision sensors within the instrument, it calculates the leakage of the product and compares it with the set upper and lower limits to determine whether the tested product is qualified.
◇Features high precision, fast response, and a simple and clear interface;
◇Equipped with a volume testing program, it can automatically calculate the volume of the product, reducing measurement errors caused by manual estimation;
◇Uses a self-developed control board and dedicated control and testing program, with high precision and strong anti-interference capability;
◇Provides a selection of various pressure and leakage rate units:
◇High-definition large screen, intuitive curve display, making the interface simple and clear;
◇Equipped with a report page, which can statistically analyze and save the test results, storing up to 100,000 sets of data;
◇The instrument is equipped with a USB interface for downloading and storing test results;
◇Supports Chinese/English interfaces to suit different customer groups;
◇Equipped with a 485 interface supporting Modbus protocol, allowing for remote control, setting, and monitoring of the test;
◇Equipped with an internal filter, greatly extending the service life of the instrument;
◇Rich external control interfaces allow the instrument to be embedded in other systems to meet the needs of automated control;
Technical Parameters
| Item | Description and Parameters | Notes |
| Equipment Model | YM-2U23A | This model is a 2-station model |
| Equipment Name | Differential Pressure Leak Detector | Automatic Pressure Regulation Type |
| Power Supply | 220VAC ±10%, 50HZ | |
| Gas Source Pressure | 0.1-2.5MPa (needs to be determined according to different models and types) | |
| Maximum Withstanding Pressure | 1.0MPa (different models have different pressure ranges, generally within twice the test pressure). | |
| Test Pressure | 10-2000KPa (test pressure range determined by different models below) | |
| Testing Principle | Instrument detection principle: Differential pressure method | |
| Test Medium | Dry, clean compressed air or nitrogen | |
| Sensor Accuracy | ±0.25%FS | |
| Time Accuracy | 0.1S | |
| Differential Pressure Range | 1000Pa (customizable) | |
| Pressure Display | 0.1KPa (test pressure display to one decimal place) | For example: 20.3/300.6KPa |
| Leakage Display Accuracy | 0.1Pa or 0.001mL/min | |
| Leakage Amount Accuracy | A leakage of 0.1mL/min or one bubble within 15 seconds in the tested object can be detected. | |
| Report Capacity | Approximately 100,000 sets (can be exported and printed via network connection) | |
| Network Interface | Uses USB expansion; connection allows for real-time parameter monitoring and report extraction. | |
| Parameter Output | Can be copied to a USB drive and input into a computer. Network output is also available (see above). | |
| Manual Pressure Adjustment | After setting the pressure, it can automatically stabilize within the set pressure range. | |
| Manual Pressure Change | The instrument can set two different pressure groups and automatically change pressure. | For example: 20.3/300.6KPa |
| IO Point Output | IO point output can control two cylinders in a fixture (two-way output). | |
| Stylus | The instrument is equipped with a stylus for setting touch screen parameters. | |
| External Dimensions | 285(W)*320(H)*360(D)mm | |
| Net Weight | Approximately 8.5Kg |
Keywords:
YM-2U23A Differential Pressure Airtightness Tester
Product Category: